GuideHow to evaluate a clinical LLM: accuracy, safety and red-teaming
deeplabel

How to evaluate radiology report generation: metrics, references and reader studies.

Text-similarity metrics will tell you a generated report reads like the reference. They will not tell you it says the right thing about the patient. This is how to measure clinical correctness, where automated metrics help and where they quietly fail, and when you need radiologists in the loop.

DeepLabel · · 11 min read

Evaluating radiology report generation means judging whether the generated report is clinically correct, not whether it reads like the reference report. A model can score well on text-similarity metrics while getting the finding, the side or the severity wrong, so a sound evaluation pairs clinical-entity and composite metrics for fast iteration with radiologist review against a defined error taxonomy for any decision that affects patients. At DeepLabel, radiologists from the BiteLabs network of 30,000+ UK and US clinicians work with PhD data scientists to build the reference standard, write the error taxonomy and run the reader review, so the numbers mean something clinically.

What makes a report clinically good?

Before you can measure a report, you have to agree what a good one does. A clinically useful report gets the findings right: the things that are present are reported, and the things that are absent are not invented. It gets the laterality right, because an opacity in the right lower lobe and the same opacity on the left lead to different patients being investigated. It gets size and severity right, because a 4 mm nodule and a 14 mm nodule sit on different follow-up pathways.

A good report also compares with prior imaging where priors exist, since "new", "stable" and "resolving" change the clinical meaning of an identical finding. The impression has to follow from the body of the report and answer the clinical question that was asked. The certainty has to be appropriate: hedging on an obvious finding is unhelpful, and false confidence on an ambiguous one is dangerous. And where a finding warrants it, the recommendation has to be safe and actionable, neither missing nor overcalling the next step. Any evaluation that does not look at all of these is measuring something narrower than report quality.

Why do BLEU, ROUGE and BERTScore mislead?

Lexical metrics such as BLEU and ROUGE-L score how much the generated text overlaps, word for word or in short sequences, with a reference. Embedding metrics such as BERTScore score how close the two are in a language model's representation space, which captures paraphrase. All three were built for machine translation and summarisation, where saying roughly the same thing in different words is the goal. In radiology the opposite is true: a single word can reverse the clinical meaning, and these metrics barely register it.

Take a worked example. Suppose the reference sentence is "There is no pneumothorax" and the model generates "There is a pneumothorax". Both are four tokens. They share three of them ("There", "is", "pneumothorax"), so the unigram overlap is 3 of 4, giving a ROUGE-1 precision and recall of 0.75 and an F1 of 0.75. The two sentences describe opposite clinical realities, one of which is a potential emergency, yet the metric calls them 75% alike. A laterality swap behaves the same way: "Opacity in the right lower lobe" against "Opacity in the left lower lobe" shares five of six tokens, an overlap of about 0.83, for a report that sends the wrong side to follow-up. BERTScore is kinder to paraphrase but has the same blind spot, because "no pneumothorax" and "a pneumothorax" are near neighbours in embedding space; negation and laterality are exactly where it is weakest.

The practical consequence is that these metrics reward a model for copying the reference's house style and phrasing, and they cannot distinguish a harmless rewording from a clinically reversed statement. They are fine as a coarse signal that output has not collapsed into gibberish. They are not a measure of clinical correctness, and a leaderboard built on them optimises for the wrong thing.

Clinical-entity metrics and their limits

Clinical-entity metrics try to fix this by scoring the medicine rather than the words. The CheXbert labeller extracts 14 CheXpert observation classes (findings such as pneumothorax, pleural effusion, cardiomegaly and support devices) from both the generated and the reference report, then computes an F1 over those labels. Because it works on presence and absence of specific findings, it catches the negation flip that ROUGE misses: "no pneumothorax" and "a pneumothorax" now land in different classes. RadGraph F1 goes further, extracting clinical entities and the relations between them (an observation located in an anatomical structure, say) and scoring the overlap of that graph, which brings in some of the structure a report carries.

These are a real improvement, but their limits matter. The label space is small and fixed: 14 observations describe a chest radiograph adequately and a knee MRI or a staging CT not at all. Both were developed on chest X-ray reports, so they do not transfer to other modalities without new schemas and new reference data. They inherit the errors of the extractor itself, so a mislabelled reference quietly becomes part of your ground truth. And they still say little about the dimensions that drive clinical decisions: size, exact location, comparison with priors, and how certain the report is. A report can score well on entity F1 and still get the measurements and the follow-up wrong.

Composite and LLM-based metrics

Two newer approaches try to close that gap. RadCliQ (Yu and colleagues, Patterns, 2023) is a composite: it combines BLEU, BERTScore, CheXbert vector similarity and RadGraph F1 into a single score that was fitted to predict the total number of errors a radiologist would assign to a report, clinically significant and insignificant combined. Because it is calibrated against radiologist error counts rather than word overlap, it tracks clinical quality more closely than any of its ingredients alone. GREEN (Ostmeier and colleagues, Findings of EMNLP, 2024) takes a different route: it uses a language model to read the generated and reference reports, identify clinically significant errors and explain them, so you get a rationale rather than only a number.

Both are useful and both come with caveats. Both were developed and validated mainly on chest X-ray reports (RadCliQ on MIMIC-CXR; GREEN validated against six radiologists' error counts on the ReXVal dataset), with only limited testing on other modalities, so their behaviour on your modality, your case mix and your reporting style is an open question until you check it. A composite score also hides which kind of error drove it, which is the thing a developer most needs to know. LLM-based grading adds its own failure modes: graders drift between model versions, and the biases documented for LLM-as-judge systems (position bias, a preference for longer answers, and self-preference, where a model favours text resembling its own, described by Zheng and colleagues in the MT-Bench and Chatbot Arena work) apply here too.

The way to use an automated grader responsibly is to validate it against clinicians the way a careful benchmark does. HealthBench (OpenAI, May 2025) is the useful precedent: its rubric criteria were written by physicians with explicit point weights, a model-based grader scored responses against them, and the team ran a meta-evaluation comparing the grader's agreement with physicians against how well physicians agreed with each other. That is the bar. Before you trust any metric or grader as a development signal, measure its agreement with your radiologists on a held-out sample, and compare that agreement with your radiologists' agreement with one another. If the metric agrees with your readers about as well as they agree with each other, it is a fair proxy for iteration. If it does not, it is a thermometer that reads the wrong temperature.

Metric familyExamplesWhat it catchesWhat it misses
Lexical overlapBLEU, ROUGE-LRough fluency and phrasing overlap with the referenceNegation, laterality, severity; rewards copying reference style
Embedding similarityBERTScoreParaphrase and semantic closenessA flipped finding barely moves the score; weak on negation
Clinical-entityCheXbert F1 (14 classes), RadGraph F1Presence or absence of defined findings, and relations between themSmall fixed label space; chest X-ray only; inherits labeller errors; weak on size, comparison and certainty
Composite, learnedRadCliQCorrelates with radiologist-counted total errors on its training dataFitted mainly to chest X-ray data (MIMIC-CXR); needs local validation; one number hides the error type
LLM-basedGREENIdentifies and explains clinically significant errorsValidated mainly on chest X-ray; grader drift and bias; needs validation against your radiologists
Expert reviewRadiologist grading against a taxonomyEverything above, with clinical significance and contextSlower and costlier; needs design, calibration and agreement measurement

The reference report problem

Every metric above compares the model against a reference report, which raises a question most leaderboards skip: is the reference actually correct? A single radiologist's report is one competent reading, not ground truth. Two good radiologists will phrase the same study differently, will differ on whether a borderline finding is worth mentioning, and will sometimes disagree on the finding itself. Scoring a model against one such report conflates two different things: whether the model is wrong, and whether it simply reads the study differently from the one radiologist who happened to dictate the reference.

The public datasets most report-generation work is built on make this sharper. MIMIC-CXR, CheXpert and IU X-ray (Open-i) are large and valuable, but their reports reflect the reporting style of particular institutions, and, like all routine clinical reports, they contain errors, omissions and hedging. A model trained and scored against them will learn that local style and inherit those errors as if they were truth. If you evaluate only against a single-reader reference, your ceiling is that reader. For anything that gates a decision, the reference standard itself needs to be built deliberately: multiple independent reads, a documented rule for resolving disagreement, and senior adjudication of the cases that matter, so that "correct" is defined by more than one person's reading on one day.

A clinical error taxonomy

To grade reports consistently you need a shared vocabulary for what can go wrong, graded by how much it matters clinically. A workable taxonomy for generated reports separates the error types, so that a trivial wording slip and a dangerous miss are never counted the same:

  • False finding: a finding reported that is not present (a hallucinated nodule, an invented effusion).
  • Missed finding: a finding that is present but not reported.
  • Wrong location or laterality: the right finding attributed to the wrong side, lobe or structure.
  • Wrong severity or size: a finding reported but mis-measured or mis-graded in a way that changes management.
  • Wrong comparison with prior: calling a stable finding new, or a growing one unchanged.
  • Inappropriate certainty or hedging: false confidence on an ambiguous finding, or needless hedging on an obvious one.
  • Unsafe or missing recommendation: no follow-up where one is warranted, or a recommendation that is wrong for the finding.

Each error is then graded for clinical significance, for example whether it would change management or could lead to harm. This is what lets you report results that a clinical team can act on: not a single similarity score, but how many reports contained a management-changing error, of which type, and how severe. It also turns the automated metrics into something checkable, because you can ask how well RadCliQ or GREEN tracks the error counts your radiologists actually assign under this taxonomy.

Designing radiologist-graded evaluation

Expert review is where clinical correctness is actually established, and it needs the same rigour as any study. Reviewers should be blinded to which system produced a report, so that knowing an output is "the AI" or "the human" does not colour the grade. You have a choice between absolute grading, where each report is scored on its own against the taxonomy, and side-by-side grading, where a reviewer compares two reports for the same study and says which is better and why. Side-by-side is sensitive for detecting differences between models; absolute grading gives you an interpretable error rate per report. Many evaluations use both.

Because a single grader is themselves one reading, a share of the cases should be double read, with two radiologists grading independently and a senior reviewer adjudicating where they disagree. That double reading is not overhead; it is how you measure whether the grading is reliable. Report agreement per error type rather than as one average: Cohen's kappa or Gwet's AC1 for whether an error class is present (Gwet's AC1 behaves better than kappa when an error type is rare and the ratings are skewed), and the intraclass correlation coefficient for counts of errors per report. If reviewers cannot agree on what counts as a missed finding, the taxonomy or the calibration needs work before the headline numbers mean anything. Calibrate reviewers on a shared set before the main read, and sample completed work as it comes in.

Grounding and clinical context

For multimodal models that read the image as well as write the report, text-level correctness is necessary but not sufficient. A model can produce the right words for the wrong reason, matching the reference by pattern without having localised the finding on the image. Where your task and your data allow it, grounding checks ask whether the region the model points to actually corresponds to the finding it reports, using overlap measures such as Dice or intersection over union against a reference region, or boundary measures such as the Hausdorff distance for how far the predicted outline strays. A report that is textually correct but ungrounded is fragile, because it will fail silently on the next case where the pattern does not hold.

The other half of context runs in the opposite direction. Good reporting uses information beyond the single image: the clinical question on the request, the patient's history, and prior studies for comparison. A model given only the current image cannot reasonably be marked down for failing to compare with a prior it never saw, and, conversely, a model that has the priors should be evaluated on whether it uses them correctly. Decide up front what context the model receives and what context the reference reader had, and make the evaluation fair to both. Mismatches here are a common and avoidable source of misleading scores.

Where each method fits

These approaches are not competitors; they answer different questions at different stages, and the mistake is to use one where another belongs. Automated metrics, including the clinical-entity and composite ones, are the right tool during development: they are quick to run on every change, so they work as regression tests that catch when a model update makes reports worse before anyone reads them. Expert review against the taxonomy is the right tool for a release decision, because only clinicians can weigh clinical significance and context, and because the automated signal is a proxy you validated, not the thing itself. A reader study is the right tool when the question is clinical effect: does using this model change what radiologists do, how accurately, and how quickly.

That last step is a study, not a metric. A fully crossed design, where every reader reads every case, gives the most statistical power for a given number of cases, a point FDA makes in its guidance on clinical performance assessment for computer-assisted detection devices, which also stresses pre-specifying the statistical analysis and notes that enriching a case set with abnormal cases is likely to alter reader performance compared with clinical practice. Fix the design, the sample size and the analysis in a statistical analysis plan before any reading begins. Regulatory strategy sits with the manufacturer and their regulatory advisers; our part is building the clinical evidence soundly.

If you are building a report-generation or multimodal imaging model and want an evaluation that measures clinical correctness rather than surface similarity, this is what we do. Our radiology annotation work builds the reference standards and error-graded reads these evaluations rest on; our medical imaging annotation service covers the same across other specialties; and our clinical validation and reader studies service designs and runs the reader study, including the sample size, the statistical analysis plan and the analysis. If you would like to talk it through, Book a scoping call.

Common questions

Evaluating report generation, answered.

Anything else, just ask on a scoping call.

Can we rely on CheXbert or RadGraph F1 if our model reports CT or MRI, not chest X-ray?

Not directly. The CheXbert labeller covers 14 observation classes defined for chest radiograph reports, and RadGraph was built on the same kind of data. Outside that distribution the label space and the extractor no longer fit what you are reporting, so you need a reference standard and a label schema designed for your modality and body area before any entity metric means anything.

Should we validate RadCliQ or GREEN on our own data before trusting them?

Yes. Both were developed and validated mainly on chest X-ray reports, with only limited testing on other modalities. Before you use either as a development signal, check it against your own radiologists’ error counts on a held-out sample, report the correlation, and treat the metric as triage for regression testing rather than evidence for a release decision.

How do we measure agreement when radiologists grade generated reports?

Grade each report against a fixed error taxonomy, then measure agreement per error type rather than as one average. For presence or absence of an error class, Cohen’s kappa or Gwet’s AC1 handle the skew when most reports lack that error; for counts of errors per report, the intraclass correlation coefficient is appropriate. Have a senior reviewer adjudicate disagreements and report the reliability alongside the results.

Can an LLM grade reports instead of radiologists for a release decision?

Use an LLM grader for fast, repeatable regression testing during development, not for the release decision on its own. If you do use one, run a meta-evaluation first: compare the grader’s agreement with your radiologists against how well two radiologists agree with each other, and watch for position, length and self-preference bias. Keep clinician review in the loop for anything that gates deployment.

How many readers and cases does a reader study on report quality need?

It depends on the effect size you expect, the variance between readers and cases, and whether the comparison is paired. A fully crossed design, where every reader reads every case, gives the most statistical power for a given number of cases. Fix the sample size and the analysis in a statistical analysis plan before any reading starts, and remember that regulatory strategy sits with the manufacturer and their regulatory advisers.

Sources

Let's solve your next clinical AI challenge.

Tell us what you're developing and we'll reply the same working day.

Discuss your project